Whern a camera first arrives from Tattile it will be configured as an access point. This article will guide you through the process of connecting to and configuring a Tattile LPR camera from factory default. 

Table of Contents


First Time Connection

Power up the camera and give it a few minutes to fully boot up.

At that point you will see the camera in your network connections list.
Note the network name reflects the seriel number of the camera In this case ANPR-2010011339
Click connect to estabolish establish a connection between your computer and the camera's hotspot.

The standard IP address for the camera coming from the factory is set at 192.168.150.1
You will also have to put the port number in your URL when trying to connect through your browser.

Open a browser and enter the camera IP and port into the address bar. In this case it will be 192.168.150.1:1080 (Where 192.168.150.1 is the camera IP and 1080 is the port number)

You will be prompted to enter a user name and password. 
Username superuser
Password superuser


You will then be directed to the Plate Reader Tab of the camera configuration.

There are Specific areas that you will need to configure.

On the Plate Reader tab you will edit:

General Settings
Event Actions Also known as TCP Events
JPEG Image Header Configuration
Plate Reader Settings

On the System tab you will edit:

Network Settings






Related Pages

Filter by label (Content by label)
showLabelsfalse
showSpacefalse
sorttitle
cqllabel = "ops-com" and space = currentSpace()


Show if
special@authenticated


Support Agent Notes

No special notes. If you feel any should be added, please add them here.